TROUBLESHOOTING
PROBABLE SUGGESTED
SYMPTOM CAUSE CORRECTION
Unit is triggered any BLUE wire is shorted to ground Disconnect the wire to see if
time it is armed. or the BWS-296 or optional sensor the symptom stops. If so, check
is not correctly adjusted. the wire for shorts or readjust
sensor fittings.
Alarm will not rearm WHITE wire is connected to pos- Check WHITE and BLU/WHT
or will not passively itive voltage, BLU/WHT wire is wires with doors closed and
arm. connected to ground, GREEN wire open, and GREEN wire with ig-
is connected to permanent posi- nition switch off and on, for
tive voltage, or pinswitch is bad. correct voltage changes. Repair
and/or rewire as needed.
Alarm will arm from Dipswitch #4 is off.VIOLET Set dipswitch #4 to ON. Check
transmitter but will wire is shorted to ground. VIOLET wire for shorts.
not passively arm.
Remote Control does Defective Remote Control. Bad Replace Remote Control or its
not arm or disarm battery. Antenna wire is battery. Un-ground antenna.
alarm. grounded.
Valet does not work. Wire from Valet switch to ground Test for switched ground at alarm
is not connected to a good ground unit. Repair or replace as needed.
or wire from switch to unit is
open. Bad switch.
Flashing output does Bad connection on WHT/ORG Check WHT/ORG wire. Connect
not work. wire or the drive polarity is a SPDT Relay to this wire and
wrong for the circuit being apply the opposite polarity to the
driven. circuit being driven.
Door locks do not Defective GRN/BLK or YELLOW Check GRN/BLK and YELLOW
lock/unlock correctly, wiring. GRN/BLK and YELLOW wires. Check vehicles door lock
or action is reversed. wires reversed, or wrong door system for method of operation.
lock wiring used. Reverse wiring to door relays.